12038 DC24V Axial Fan Alternative

12038 DC24V Axial Fan Domestic Replacement

In automation equipment, power supplies, and telecom gear, 12038-size DC24V axial fans are often replaced by domestic alternatives for imported DC fans. JIEFENGFAN JF12038D24HBL-5 can be matched by dimensions, airflow, and static pressure. See DC axial fan product list.

JF12038D24HBL-5 Parameters

Item Specification
Dimensions 119.5 × 119.5 × 38.3 mm (mounting hole spacing 105 × 105 mm)
Power supply 24V / 48V DC
Power 96.0 / 172.8 W
Airflow approx. 205.4 / 293.4 CFM
Static pressure approx. 2.21 / 2.95 inch-H₂O
Speed approx. 7000 / 10000 RPM
Noise approx. 72.3 dBA
Protection rating IP43
Operating temperature -30℃ ~ +70℃

Replacement Comparison Notes

Item Notes
Dimensions ~120×120mm class, ~38mm thickness, hole pattern per drawing
Power DC24V; confirm power supply capacity and inrush current
Airflow & pressure Select by system resistance; don't compare maximum airflow alone
Signal functions PWM speed control / FG tachometer / RD alarm

For further selection, prepare mounting dimensions, voltage, target airflow/static pressure, operating environment, continuous operation requirements, and control function needs, then compare against product parameters, or contact us for selection support.

Frequently Asked Questions (FAQ)

Is there a domestic replacement for 12038 DC24V fans?

JIEFENGFAN DC 12038 series offers 24V DC axial fans as replacement candidates for imported DC fans of the same size. Some models support PWM, FG, and RD functions. Representative model: JF12038D24HBL-5.

What signal functions do JIEFENGFAN DC24V fans offer?

Some DC models can be configured with PWM speed control, FG tachometer pulse output, and RD run/alarm signals. Exact functions depend on the model specification.

Can I directly replace a Delta same-size 12038 DC24V fan?

Similar dimensions make it a candidate, but verify voltage, current, airflow-pressure curve, tachometer signal definition, and wiring. Obtain samples for testing first.

What should I provide when sourcing a DC24V replacement fan?

Provide mounting dimensions, voltage, target airflow or heat dissipation, system resistance, noise requirements, and PWM/FG/RD functional needs.